Our Life Safety educational resource hub is full of healthcare knowledge to help you be better informed of the changing world around you.
Rather than sit back and act on decisions made by others, we are leading the charge as it relates to identifying best practices for Life Safety Code® and compliance. We have real people that give our clients real information that can be put into practice.
Interested in reading our experts' take on Life Safety? Then subscribe to our free blog below! We discuss readers' questions, share interesting observations from the field, and more.
Q: Do all of the screw heads in a psych ward need to be tamper proof? A: There is no specific code or standard that addresses screw heads in a …
Continuing in a series of strange things that I have seen while consulting at hospitals... Doors to medical gas storage rooms are required to be fire-rated. Fire-rated doors cannot have …
Q: We have metal "bumpers" (for lack of a better term) that were fabricated onsite at our hospital, that are used to keep carts and beds for damaging the doors …
Understand practical applications of the NFPA 101 Life Safety Code®! Learn from a Life Safety surveyor on what to prepare for during surveys! A 2-day Boot Camp on the comprehensive …
Q: I have two questions regarding spark-ignited emergency power generators: What maintenance tests are required for natural or propane Generators? Are load bank test required for Natural gas or Propane …
Q: I work in the Central Processing department and yesterday they upped the temperature to 72 - 73 degrees in decontam and the clean side. I always thought it had …
Continuing in a series of strange things that I have seen while consulting at hospitals... These portable X-ray units were double-parked in the adjunct corridor to the radiology control room …
Q: I’m butting heads with our Infection Control group regarding holes in construction barriers. They have started requiring the contractors to make the construction sites negative air-pressure, which is fine, …
Understand practical applications of the NFPA 101 Life Safety Code®! Learn from a Life Safety surveyor on what to prepare for during surveys! A 2-day Boot Camp on the comprehensive …
Q: Is there a codified requirement for doors in a cabinet mounted in a hospital egress corridor? We have worked on projects when a nurse server; i.e., pass through cabinet, …
Q: We are a fully sprinkled hospital. Is it permissible to hang Christmas garland from the ceiling, as long as we stay away from sprinkler heads and abide by the …
Q: Are sprinklers required in patient room lockers for existing facilities? A: No… Section 8.1.1 (7) of NFPA 13-2010 says furniture not intended for occupancy is not required to be …
Continuing in a series of strange things that I have seen while consulting at hospitals... Remember I have been saying that clearance must be maintained in front of electrical panels …
Q: If a smoke detecting device is disabled for a breathing treatment (often for several days), what sort of fire watch, notification or signage is necessary? A: None. Fire watches …
Understand practical applications of the NFPA 101 Life Safety Code®! Learn from a Life Safety surveyor on what to prepare for during surveys! A 2-day Boot Camp on the comprehensive …
Q: It appears that the LSC allows up to 50 square feet of unprotected storage but also includes language that suggests it may need to be protected in accordance with …
On October 23, 2018, I posted a picture of this illuminated pumpkin and wrote that the extension cord could not be used since Article 400.8 (3) of NFPA 70-2011 says …
Q: Under CMS, is it possible to use a UL listed power cord (extension cord), permanently attached to the equipment assembly providing it meets the ampacity requirements? If yes, what …
Continuing in a series of strange things that I have seen while consulting at hospitals... Do you ever think about your corridor wall sconce light fixtures projecting more than 4-inches into …
Q: We recently had our fire sprinkler inspection and was informed by the vendor that with the new 2012 LSC updates, every fire hose connection valve weather it is 1½ …
Understand practical applications of the NFPA 101 Life Safety Code®! Learn from a Life Safety surveyor on what to prepare for during surveys! A 2-day Boot Camp on the comprehensive …
Q: I had an independent Life Safety inspection and during the inspection the inspector cited me for my 2-hour fire door frames not having a fire rating visible. I explained …
Q: You once said this regarding bulletin board decorations: If the bulletin board is decorated then yes; it is counted as decorations. But if the bulletin board is simply communication …
Continuing in a series of strange things that I have seen while consulting at hospitals... We already talked about this issue on 'Strange Observations - Part 20' posted April 5, …
We help you be better informed of the changing world around you. Our life safety blog answers your real world questions!