Our Life Safety educational resource hub is full of healthcare knowledge to help you be better informed of the changing world around you. 

Rather than sit back and act on decisions made by others, we are leading the charge as it relates to identifying best practices for Life Safety Code® and compliance. We have real people that give our clients real information that can be put into practice.

Interested in reading our experts' take on Life Safety? Then subscribe to our free blog below! We discuss readers' questions, share interesting observations from the field, and more.

Inspection & Maintenance (Electrical)Door LocksAccreditationTesting (Fire Detection Systems)CMS

Q: Is there a code requirement for testing magnetic-locking devices, for a facility maintenance director? A: There is a requirement in NFPA 72-2010, section 14.4.5 that all interface devices (ie …

Brad Keyes, CHSP | Apr 29, 2019
Testing (Generators)Equipment (Generators)Inspection & Maintenance (Generators)

Q: We are going to have temporary generators onsite for two months that we will use during our construction project to replace the main power distribution gear for our bed …

Brad Keyes, CHSP | Apr 26, 2019
ArticleHVACSprinklers

Continuing in a series of strange things that I have seen while consulting at hospitals... This is another picture of sprinkler pipe supported from HVAC ductwork, similar to last week's …

Brad Keyes, CHSP | Apr 25, 2019
VentilationHVAC

Q: We have two small processing rooms in a hospital where they clean and reprocess vaginal probes, using the chemical RESERT. Should these rooms be held to the same standard …

Brad Keyes, CHSP | Apr 24, 2019
Joint CommissionPortable Space Heaters

Q: Could you please clear up a concern related to section 19.7.8 of the 2012 Life Safety Code, that addresses Portable Space-Heating Devices? Section 19.7.8 (1) states such devices are …

Brad Keyes, CHSP | Apr 22, 2019
ArticleHVACSprinklers

Continuing in a series of strange things that I have seen while consulting at hospitals... Some organizations fail to install sprinklers underneath the ductwork that is 48-inches wide or wider …

Brad Keyes, CHSP | Apr 18, 2019
Fire AlarmFire Alarm Notification DevicesOn Call Sleeping Rooms

Q: In regards to audio/visual strobes in staff sleeping rooms, is it required for them to hear the fire alarm system? A: According to section 26.3.4.5.1 of the 2012 Life …

Brad Keyes, CHSP | Apr 17, 2019
Fire ExtinguishersOperating Room

Q: At our hospital there is some question about which type of portable fire extinguisher should be installed in our operating rooms. We can't find an actual requirement for this …

Brad Keyes, CHSP | Apr 15, 2019
Fire Extinguishers

Q: Do fire extinguishers that are placed in patient care areas of a hospital have to be placed in a wall cabinet, or can they hang from the wall? A: …

Brad Keyes, CHSP | Apr 12, 2019
ArticleUtilities

Continuing in a series of strange things that I have seen while consulting at hospitals... Ah... This is plain ugly. As you can see, water ran into this electrical junction-box …

Brad Keyes, CHSP | Apr 11, 2019
Fire AlarmDuct DetectosSmoke Dampers

Q: With regard to testing duct detectors in a hospital, I understand that on an annual basis the automatic shutdown of the AHU's must be verified when duct detectors are …

Brad Keyes, CHSP | Apr 10, 2019
Automatic Transfer SwitchesEquipment (Generators)Storage (Generators)

Q: I am a consultant and I visited an ASC that had a natural gas generator housed indoors, located in the basement of the facility. The ATS switch was located …

Brad Keyes, CHSP | Apr 8, 2019
Storage (Life Safety Code)SeparationFire BarrierParking GarageOccupancies

Q: We have a three-story parking structure attached to a hospital. The top floor of the parking structure is not covered and is open to the atmosphere. Is the exterior …

Brad Keyes, CHSP | Apr 5, 2019
ArticleStairs

Continuing in a series of strange things that I have seen while consulting at hospitals... The maximum rise in a existing construction step is 8-inches. The step in the picture …

Brad Keyes, CHSP | Apr 4, 2019
Fire AlarmFire Alarm Notification DevicesOperating Room

Q: Can you explain the fire alarm notification appliance location requirements as it pertains to the operating room? I seem to recall that there's no requirement to have them in …

Brad Keyes, CHSP | Apr 3, 2019
StairwellsSignage (Life Safety Code)Signs (Life Safety Code)Egress

Q: Can signage, other than that specifically required for inside a fire exit stairwell according to the LSC, be placed inside a fire exit stairwell? A: Technically… no. According to …

Brad Keyes, CHSP | Apr 1, 2019