Our Life Safety educational resource hub is full of healthcare knowledge to help you be better informed of the changing world around you.
Rather than sit back and act on decisions made by others, we are leading the charge as it relates to identifying best practices for Life Safety Code® and compliance. We have real people that give our clients real information that can be put into practice.
Interested in reading our experts' take on Life Safety? Then subscribe to our free blog below! We discuss readers' questions, share interesting observations from the field, and more.
Q: Has there been an update to the definition of time by TJC/CMS? I'm looking at quarterly fire drills right now, but any changes/clarification on the definition for all intervals …
Q: Now that we have some clarification from CMS on annual door inspection [See CMS S&C memo 17-38, dated July 28, 2017], I wanted to see if there was any …
Q: I'd like some clarification concerning the new requirement for annual fire door inspections: NFPA 101 2012, Chapter 7.2.1.15 States "Where required by Chapters 11 through 43, the following door …
Q: Do doors in smoke barriers in healthcare occupancies have to be tested and inspected? Section 7.2.1.15.2 of the 2012 Life Safety Code says smoke door assemblies have to be …
Q: In regards to fire door inspections, what are the qualifications of the person to perform the inspection? A: NFPA 80-2010, section 5.2.3.1 says fire doors must be tested by …
Q: Our organization is accredited by Joint Commission. I know for inspection purposes we need to have the current year plus that past three years of documentation for LS and …
Q: In regards to the new annual fire rated door assembly inspection, are we to inspect every door that has a fire rating or the doors that are located in …
Q: For off-site satellite facilities, where the building is not owned by the hospital but where the space inside the building is licensed by the hospital, are monthly fire extinguisher …
Q: What are the testing requirements for a two story medical office building with a fire alarm system and sprinkler system? I believe we are required to have an annual …
My recent series of articles on Documentation created quite a bit of response. One individual had this question: "What is your opinion of documentation being kept electronically rather than in …
What do we do with smoke dampers now that the hospital is fully protected with sprinklers? That question is asked many times by facility managers who are looking to cut …
Many of you may be familiar with the Joint Commission's standard practice for inaccessible fire dampers: If the fire damper is inaccessible during the required testing period, the hospital can choose …
Fire alarm test reports are the number one item that surveyors look at during the document review session. It is also the number one document that draws the most findings …
Q: What are the testing frequencies for fire alarm panel batteries and where do you find this requirement? A: The testing frequencies for batteries for fire alarm control panels (including …
As mentioned in last week's posting, The Joint Commission announced changes to their standards that takes affect January 1, 2014. We discussed already the change they are making with time …
Joint Commission has announced a couple of subtle, yet far-reaching changes to their standards to become effective January 1, 2014. One of them has to do with how they define …
Q: What is the required inspection frequency on sprinkler systems for a building classified as business occupancy? Is it less than what would be required for the main hospital? A: …
One of the requirements that CMS and Joint Commission surveyors is requesting from hospitals and nursing homes is documentation that the elevators have been tested for 'Recall'. Elevator recall is a test …
Q: During a recent survey, the inspector cited us for not exercising our circuit breakers downstream of our generator. Does the LSC require annual exercising of all circuit breakers between …
We help you be better informed of the changing world around you. Our life safety blog answers your real world questions!